Data Encryption in Predictive Intelligence Solutions

Predictive Intelligence data encryption support depends on the encryption type used for training data. Field Encryption and FDE are supported; Edge Encryption is not supported for training solutions. For Field Encryption, the sharedservice.worker user needs the encryption module role used to encrypt the data. Check that requirement before planning a training run.

Check Predictive Intelligence data encryption support

Start with the fields and records you intend to use, then establish which encryption technology applies to them. A statement that the instance uses encryption is too broad to settle training compatibility. The decision needs the named encryption type and, for Field Encryption, the role associated with the encryption module.

Keep the review tied to one solution. Record the proposed training fields, the encryption type affecting those fields, and who can verify the configuration. This is a recommended planning record, rather than an additional Predictive Intelligence setting. It gives the people responsible for security and model design a shared question to resolve.

For the surrounding design work, use the guide to machine learning solution definitions. Bring the encryption decision into that work before treating the proposed inputs as ready for training. Otherwise, a solution can appear complete on paper while a required access condition remains unresolved.

  • Field Encryption: supported for training, with a specific encryption module role requirement for sharedservice.worker.
  • Edge Encryption: unsupported for training Predictive Intelligence solutions.
  • FDE (Full Disc Encryption): supported for training, without a separate encryption module role condition.

Keep these outcomes distinct in the review. A supported encryption type answers a compatibility question. It does not, by itself, establish that the selected fields are appropriate, that the records are suitable examples, or that the organization has approved their use for this purpose.

Check the Field Encryption role for sharedservice.worker

For Field Encryption, the access check concerns the sharedservice.worker user. That user must have the same encryption module role used for the encryption. Match the actual module role; a broad description such as “the worker has access” leaves the decisive detail untested.

A recommended review sequence is to identify the encryption module used for the proposed data, establish its encryption role, and compare that role with the roles assigned to sharedservice.worker. Ask the administrator responsible for role assignments to resolve a mismatch through the organization’s access process. Record the role name and the review outcome with the solution’s preparation notes.

Do not substitute the access of the person configuring the solution for the worker user’s access. The requirement names sharedservice.worker, so the review needs evidence about that account. An administrator’s ability to inspect a field does not answer whether the named worker user meets the encryption module role requirement.

Separate finding the required role from approving a change to that account. The required role depends on the encryption module used for the data. Use the actual module configuration and your established administrative process instead of guessing a role from its name.

Once the role question is settled, continue with Predictive Intelligence solution configuration. Keep the encryption check attached to the selected inputs so that a later change in fields prompts a fresh review of the relevant module and role.

Handle Edge Encryption as a training design constraint

Edge Encryption is not supported for training Predictive Intelligence solutions. Treat that result as a constraint on the proposed design. Repeating a training attempt without changing the underlying plan does not resolve the documented incompatibility.

If your intended examples depend on Edge Encryption, pause the decision to use those examples. Ask the data owner and security owner to evaluate whether a different approved set of inputs can meet the business need. Frame this as a design review, with the required prediction and the permissible data both visible.

Avoid turning a compatibility issue into an informal request to weaken protection. Do not assume that a workaround makes Edge Encryption supported for training. Any proposal to change how data is protected needs its own security decision, separate from the pressure to complete a model. The training plan should reflect the approved outcome of that discussion.

For example, suppose a proposed ticket classifier relies on a protected text field and the review identifies Edge Encryption. The next question is whether the classifier’s objective can be met with other approved inputs. That is a planning question to investigate, not a promise that an alternative input set will produce an acceptable model.

For help planning this work, see ServiceNow implementation.

Keep the FDE result within its stated scope

FDE is supported for training Predictive Intelligence solutions. The sharedservice.worker encryption module role condition applies to Field Encryption. Keep that distinction clear when documenting the review; do not transfer the Field Encryption condition to another encryption type without evidence.

At the same time, avoid using the FDE result as a blanket security conclusion. It answers whether that encryption type is supported for training. It does not establish an organization’s retention policy, permission to use a particular record set, or acceptance of a particular prediction use case.

A concise review note can therefore contain two separate outcomes: the encryption compatibility result and the organization’s decision about the proposed training data. This prevents a technical “supported” entry from being mistaken for approval to include sensitive material in a solution.

If multiple protections appear in your inventory, record them separately and investigate their relevance to the selected inputs. Do not collapse a mixed configuration into “FDE supported” and leave other identified encryption types unexamined. Your planning record should preserve the distinction between the technologies involved.

Record a training readiness decision that can be reviewed

Build the readiness decision around evidence someone else can inspect. A recommended record contains the solution’s purpose, the selected inputs, their encryption type, the compatibility outcome, and the Field Encryption role check where applicable. Add the person responsible for resolving an open issue and the decision needed before proceeding.

  1. Describe the prediction the solution is intended to support and identify the proposed input fields.
  2. Verify the encryption type affecting those inputs with the responsible administrator.
  3. Apply the corresponding training support result and record any unresolved condition.
  4. For Field Encryption, verify the required module role against sharedservice.worker.
  5. Keep the data owner’s approval and the technical compatibility outcome visible as separate decisions.

Check behavior on your instance and release. Brazil, Australia, Zurich, and Yokohama use the label Field Encryption; Xanadu uses Column Level Encryption for the supported entry carrying the worker role condition. Preserve the release context in your notes so an older label does not cause confusion during review.

If a training issue remains after this check, keep the observed problem separate from assumptions about its cause. Record the affected solution, the selected data, the encryption result, and what you actually observed. The Predictive Intelligence troubleshooting guide provides the next route for investigating the broader issue.

Retain the decision with the solution rather than leaving it in a conversation. When someone proposes a new input field, the record gives them a concrete starting point: determine how that field is protected, then decide whether the existing readiness conclusion still applies.

For an unresolved item, write down the missing evidence explicitly. For example, distinguish an unknown encryption type from a known Field Encryption configuration whose worker role assignment still needs verification.

Questions to resolve during the encryption review

What should a handoff to the security owner contain?

Provide the prediction objective, the proposed inputs, and the specific decision you need. Ask for an outcome that can be recorded with the solution. A request framed around a named field and training purpose is easier to assess than a general request to approve machine learning.

Can a successful training run serve as a compliance signoff?

Keep technical results and governance approval separate. A completed run can be recorded as an operational result, but the organization’s approval process still needs its own evidence and decision. Do not make the training team responsible for inferring an approval that nobody has given.

Who should own an unresolved encryption question?

Assign it to someone who can obtain the encryption configuration and coordinate the necessary decision. Record an owner rather than leaving the issue with “the project.” This is a recommended coordination practice; it does not imply a particular ServiceNow role or permission.

How should an upgrade review use the earlier decision?

Use it as a list of assumptions to revisit: the selected inputs, their protection, the worker role evidence, and the approval context. Preserve what was checked previously while recording the new review outcome. That makes changes visible without treating the earlier decision as permanent.